{"product_id":"2-000-gpd-static-auto-fill-amp-flush-ro-filter-system-wall-mounted","title":"2,000 GPD Static AUTO Fill \u0026amp; Flush RO Filter System – Wall Mounted","description":"\u003ch2 data-section-id=\"1t4i59v\" data-start=\"0\" data-end=\"69\"\u003e2,000 GPD Static AUTO Fill \u0026amp; Flush RO Filter System – Wall Mounted\u003c\/h2\u003e\n\u003cp data-start=\"71\" data-end=\"367\"\u003e\u003cstrong data-start=\"71\" data-end=\"195\"\u003eFully automated 4-stage pure water filtration system producing up to 2,000 gallons (9,500 litres) of pure water per day.\u003c\/strong\u003e\u003cbr data-start=\"195\" data-end=\"198\"\u003eDesigned for professional window cleaning businesses that require reliable, high-volume pure water production with automatic filling and membrane flushing functionality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ewvfoo\" data-start=\"374\" data-end=\"418\"\u003eFully Automated Pure Water Production\u003c\/h3\u003e\n\u003cp data-start=\"420\" data-end=\"577\"\u003eThis advanced \u003cstrong data-start=\"434\" data-end=\"471\"\u003ewall-mounted RO filtration system\u003c\/strong\u003e automatically manages the entire water production process for maximum efficiency and minimal maintenance.\u003c\/p\u003e\n\u003cp data-start=\"579\" data-end=\"604\"\u003eThe system automatically:\u003c\/p\u003e\n\u003cul data-start=\"606\" data-end=\"878\"\u003e\n\u003cli data-section-id=\"1qw9yoh\" data-start=\"606\" data-end=\"642\"\u003eFlushes the RO membrane at startup\u003c\/li\u003e\n\u003cli data-section-id=\"pg60r6\" data-start=\"643\" data-end=\"690\"\u003eFlushes the membrane every hour for 5 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"ixtr6g\" data-start=\"691\" data-end=\"742\"\u003eDetects when water is used from your holding tank\u003c\/li\u003e\n\u003cli data-section-id=\"1q43v4n\" data-start=\"743\" data-end=\"792\"\u003eAutomatically refills the tank when levels drop\u003c\/li\u003e\n\u003cli data-section-id=\"1541nro\" data-start=\"793\" data-end=\"833\"\u003eStops production when the tank is full\u003c\/li\u003e\n\u003cli data-section-id=\"pe5yqa\" data-start=\"834\" data-end=\"878\"\u003eControls a 240v booster pump automatically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"880\" data-end=\"964\"\u003eSimply install the system and enjoy fully automated pure water production on demand.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iaqnpk\" data-start=\"971\" data-end=\"990\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-start=\"992\" data-end=\"1314\"\u003e\n\u003cli data-section-id=\"u9y5sz\" data-start=\"992\" data-end=\"1045\"\u003eProduces up to \u003cstrong data-start=\"1009\" data-end=\"1045\"\u003e2,000 GPD \/ 9,500 litres per day\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jzv5t0\" data-start=\"1046\" data-end=\"1088\"\u003eAutomated fill and membrane flush system\u003c\/li\u003e\n\u003cli data-section-id=\"1u4ab6z\" data-start=\"1089\" data-end=\"1128\"\u003eAutomatically stops when tank is full\u003c\/li\u003e\n\u003cli data-section-id=\"uowb29\" data-start=\"1129\" data-end=\"1172\"\u003eCompatible with 240v booster pump control\u003c\/li\u003e\n\u003cli data-section-id=\"ss0bzm\" data-start=\"1173\" data-end=\"1223\"\u003eReduced membrane maintenance and longer lifespan\u003c\/li\u003e\n\u003cli data-section-id=\"12d9z7f\" data-start=\"1224\" data-end=\"1275\"\u003eIdeal for commercial and multi-vehicle operations\u003c\/li\u003e\n\u003cli data-section-id=\"1c7er7z\" data-start=\"1276\" data-end=\"1314\"\u003eReliable on-demand pure water supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"9jse2e\" data-start=\"1321\" data-end=\"1343\"\u003eSystem Includes\u003c\/h3\u003e\n\u003cul data-start=\"1345\" data-end=\"1583\"\u003e\n\u003cli data-section-id=\"1jwxlix\" data-start=\"1345\" data-end=\"1384\"\u003e2 × 20” pre-filters in black housings\u003c\/li\u003e\n\u003cli data-section-id=\"tqswzt\" data-start=\"1385\" data-end=\"1419\"\u003e1 × 40” low-pressure RO membrane\u003c\/li\u003e\n\u003cli data-section-id=\"141kf1s\" data-start=\"1420\" data-end=\"1456\"\u003eCarbon-wrapped RO membrane housing\u003c\/li\u003e\n\u003cli data-section-id=\"1j42zq7\" data-start=\"1457\" data-end=\"1507\"\u003e1 × 11L DI resin vessel with quick-release ports\u003c\/li\u003e\n\u003cli data-section-id=\"19trsq7\" data-start=\"1508\" data-end=\"1543\"\u003eAutomated fill \u0026amp; flush controller\u003c\/li\u003e\n\u003cli data-section-id=\"161tq9p\" data-start=\"1544\" data-end=\"1583\"\u003eAutomatic booster pump control system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lx8ky\" data-start=\"1590\" data-end=\"1623\"\u003e4-Stage Filtration Process\u003c\/h3\u003e\n\u003ch4 data-start=\"1625\" data-end=\"1659\"\u003eStage 1 – Sediment Filtration\u003c\/h4\u003e\n\u003cp data-start=\"1660\" data-end=\"1707\"\u003eRemoves dirt, rust, sand, and larger particles.\u003c\/p\u003e\n\u003ch4 data-start=\"1709\" data-end=\"1741\"\u003eStage 2 – Carbon Filtration\u003c\/h4\u003e\n\u003cp data-start=\"1742\" data-end=\"1824\"\u003eReduces chlorine, VOCs, pesticides, and contaminants that can damage RO membranes.\u003c\/p\u003e\n\u003ch4 data-start=\"1826\" data-end=\"1856\"\u003eStage 3 – Reverse Osmosis\u003c\/h4\u003e\n\u003cp data-start=\"1857\" data-end=\"1958\"\u003eHigh-efficiency 40” low-pressure RO membrane removes dissolved solids with excellent rejection rates.\u003c\/p\u003e\n\u003ch4 data-start=\"1960\" data-end=\"1993\"\u003eStage 4 – DI Resin Polishing\u003c\/h4\u003e\n\u003cp data-start=\"1994\" data-end=\"2064\"\u003eFinal DI stage removes remaining TDS for spotless pure water cleaning.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ppmkxh\" data-start=\"2071\" data-end=\"2105\"\u003eWater Pressure Requirements\u003c\/h3\u003e\n\u003cul data-start=\"2107\" data-end=\"2266\"\u003e\n\u003cli data-section-id=\"rqxv2h\" data-start=\"2107\" data-end=\"2154\"\u003eRecommended operating pressure: \u003cstrong data-start=\"2141\" data-end=\"2154\"\u003e60–90 PSI\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rzabl5\" data-start=\"2155\" data-end=\"2207\"\u003eWater pressure below 50 PSI may reduce performance\u003c\/li\u003e\n\u003cli data-section-id=\"7m4jct\" data-start=\"2208\" data-end=\"2266\"\u003eBooster pump recommended for low-pressure mains supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2268\" data-end=\"2367\"\u003eThe integrated controller can automatically manage a compatible booster pump during filling cycles.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17kpd1p\" data-start=\"2374\" data-end=\"2390\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul data-start=\"2392\" data-end=\"2578\"\u003e\n\u003cli data-section-id=\"4rdslp\" data-start=\"2392\" data-end=\"2431\"\u003eCommercial window cleaning businesses\u003c\/li\u003e\n\u003cli data-section-id=\"15ro7o2\" data-start=\"2432\" data-end=\"2458\"\u003eMulti-vehicle operations\u003c\/li\u003e\n\u003cli data-section-id=\"19uzjtz\" data-start=\"2459\" data-end=\"2494\"\u003eHigh-volume pure water production\u003c\/li\u003e\n\u003cli data-section-id=\"13m7qji\" data-start=\"2495\" data-end=\"2530\"\u003eGarage and workshop installations\u003c\/li\u003e\n\u003cli data-section-id=\"8tbuic\" data-start=\"2531\" data-end=\"2578\"\u003eBusinesses wanting automated water production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1m6p1q2\" data-start=\"2585\" data-end=\"2619\"\u003eEfficient \u0026amp; Low Maintenance\u003c\/h3\u003e\n\u003cp data-start=\"2621\" data-end=\"2666\"\u003eThe automated membrane flushing system helps:\u003c\/p\u003e\n\u003cul data-start=\"2668\" data-end=\"2792\"\u003e\n\u003cli data-section-id=\"1o51zmj\" data-start=\"2668\" data-end=\"2694\"\u003eExtend membrane lifespan\u003c\/li\u003e\n\u003cli data-section-id=\"1j4qv5p\" data-start=\"2695\" data-end=\"2726\"\u003eImprove filtration efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"gmhxx5\" data-start=\"2727\" data-end=\"2760\"\u003eReduce maintenance requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1a3ufr1\" data-start=\"2761\" data-end=\"2792\"\u003eLower long-term running costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2794\" data-end=\"2908\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eWith automatic refill detection, your holding tank stays topped up and ready for work without manual intervention.\u003c\/p\u003e","brand":"EMKO Industrial","offers":[{"title":"Default Title","offer_id":59641307824462,"sku":null,"price":2375.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/6915\/8990\/files\/2000GPDAutoROSystem.png?v=1778615643","url":"https:\/\/www.emkoindustrial.ie\/products\/2-000-gpd-static-auto-fill-amp-flush-ro-filter-system-wall-mounted","provider":"EMKO Industrial","version":"1.0","type":"link"}